SCA_DelaySensor(SCA_ISensor)¶
base class — SCA_ISensor
-
class
bge.types.
SCA_DelaySensor
(SCA_ISensor)¶ The Delay sensor generates positive and negative triggers at precise time, expressed in number of frames. The delay parameter defines the length of the initial OFF period. A positive trigger is generated at the end of this period.
The duration parameter defines the length of the ON period following the OFF period. There is a negative trigger at the end of the ON period. If duration is 0, the sensor stays ON and there is no negative trigger.
The sensor runs the OFF-ON cycle once unless the repeat option is set: the OFF-ON cycle repeats indefinately (or the OFF cycle if duration is 0).
Use
SCA_ISensor.reset
at any time to restart sensor.-
delay
¶ length of the initial OFF period as number of frame, 0 for immediate trigger.
Type: integer.
-
duration
¶ length of the ON period in number of frame after the initial OFF period.
If duration is greater than 0, a negative trigger is sent at the end of the ON pulse.
Type: integer
-
repeat
¶ 1 if the OFF-ON cycle should be repeated indefinately, 0 if it should run once.
Type: integer
-